Dry Type Design
The CLMD capacitor has a dry type dieelectric which minimises risk
of leakage and environmental pollution.
Very Low Losses
Dieelectric losses within the CLMD capacitor are surrounded by
vermiculite - an inorganic
Long-Life Self-Healing
In the event of a fault developing in the dielectric of the capacitor, the adjacent metallise delectrode is immediately vaporised,
thereby isolating the fault and preventing cascade
Safety
All elements within the CLMD capacitor are surrounded by vermiculite - an inorganic, inert, fireproof and non-toxic granular material. In the event of any failure the vermiculite absorbs the energy produced within the capacitor box, extinguishing any possible flames and ensuring safety.
Unique Sequential Disconnector
A unique sequential protection system within the CLMD capacitor ensures that each individual element can be disconnected from the circuit when required.
Easy to Install
The CLMD capacitor is lightweight & compact and therefore easy to handle and install.
High Reliability
The use of robust terminals in place of fragile porcelain bushings in the CLMD capacitor removes the risk of damage during installation and reduces maintenance requirements.
Security
Thermal equalizers which surround each capacitor element provide effective heat dissipation. The CLMD capacitor is also equipped with discharge resistors.
International Standard
The CLMD capacitors comply with the requirements of IEC831-1&2 liS 13340; ISO 9001 and ISO 14001 certification and assures conformance to international standards.
SALIENT FEATURES OF S 270 SERIES MCB
Breaking capacity - 10kA in accordance with IEC 898, 15kA as per IEC 947.
Tripping characterstics - C, D, K, & Z curve.
Dimensions of single pole – 90 x 17.5 x 68 (H x W x D).
Terminals IP20, housing material with the maximum self-extinguishing degree, (VO level with1.6 mm thickness)
Endurance 20,000 operations.
Trip-free mechanism.
Class 3 limitation.
Suitable for -25° to +55° ambient temperatures.
Low watt losses per pole.
Standards: Conforms to IS888281 / IEC60898 and IEC947/2 (for K & Z curve MCB)
Dimension :
RCBO type DS971 & DS671 83x62x35.6 (HxDxW)
RCBO type DS674 94x68x105 (HxDxW) (In < 32A)
RCBO type DS674.94x68x105 (HxDxW) (In > 40A)
RCBO type F360 94x68x35 (HxDxW) (2P)/W:70(4P)
SALIENT FEATURES OF RCDs
Rated breaking capacity of RCBOs is 10kA as per IEC 1009
and 15kA as per IEC 947 & available with C curve.
2P RCBOs type DS971 & DS671 are available in 2-pole modules.
Electrical Life: 10,000 operations.
SALIENT FEATURES OF DISTRIBUTION
BOARDS
Total safety insured through provision of an intermediate plate to avoid exposure to live parts, even when door is open.
Vertical 3 phase neutral distribution boards with 250A MCCB as incomer.
Busbar and wire sets supplied as standard, along with all boards.
Wide range
Aesthetic design